Diesel generator "Könner & Söhnen" KS 13-2DEW 1/3 ATSR

Voltage230/400
Max power (230V)8.1 kW
Max power (400V)11.25 kVA
Nominal power (400V)10.63 kVA
Engine startElectric
Outlets1 x Schuko 230 V, 1 x CEE 230 V 32 A, 1 x CEE 400 V 16 A, 1 x CEE 400 V 32 A, Contact strip
Special functionsVTS 230/400 V, ATS output, Preheater function, V-twin two-cylinder, Soundproof antivandal housing, Water cooled engine

5399 *

The generators of this series are developed on the basis of modern heavy-duty two-cylinder watercooled engines (18 hp), increased service life (more than 3000 operating hours). Models KS 13 diesel generators from TM Könner & Söhnen feature a unique VTS phase switching system suitable for singlephase (230V) or three-phase (400V) operation with almost no loss of power. Mini-power plants have two design types: exposed, equipped with LED-display (voltage, frequency, working hours) and enclosed in a soundproof anti-vandal housing with a multifunctional controller and remote control.

All generators of this series are suitable for connecting the АТS (automatic transfer switch) system and equipped with an automatic monitoring system for all key indicators of the operating status: overload protection, automatic engine stop at low oil level, fuel level sensor. HEAVY DUTY series generators are intended for use not only as a backup power source, but also for continuous operation.

HIGH-PERFORMANCE TWO-CYLINDER ENGINE

High-performance optimally balanced V-twin water-cooled two-cylinders four-stroke engine (18 hp), which ensures reduced vibration of the generator during operation and it has the enlarged motor resource.

Housing

All-season soundproof antivandal housing provides effective protection for the generator and extends its service life. The housing is equipped with handles and casters for easy handling.

ERGONOMIC CONTROL PANEL

The user-friendly ergonomic control panel allows easy control of the whole device, requires no special skills, and is equipped with sockets designed for removal of full power delivered by the generator.

SMARTGEN MULTIFUNCTION DIGITAL CONTROLLER

  1. Digital display shows operating voltage of generator
  2. Power display
  3. Multifunction display shows the current, frequency, battery voltage, total operating hours (maximum 999 hours), engine and generator temperature. The controller also protects the engine from over- and undervoltage, under- and overfrequency, overload and overtemperature shown on the multifunction display.
  4. Function switching buttons - the parameters displayed can be adjusted by pressing the touch buttons (UP, DOWN, LEFT, RIGHT)
  5. The indicator shows low oil pressure, when it appears - the engine will be turned off immediately

CONTACT STRIPE

High-performance two-cylinder diesel generators from TM Könner & Söhnen are equipped with top-notch contact strips for connecting electrical cables, which allows removing the full power delivered by the unit.

Preheater function

All Heavy Duty series generators are equipped with a preheat function, which allows you to easily start a generator in winter.

ATS output

KS ATS 4/63HD
339 / 299
Battery voltage12 V DC
Voltage230/400
Current (max)63 A
Working environmentfrom -10°C to +55°C; humidity: ⩽60%
Storage environmentfrom -10°C to +70°C; humidity: ⩽60%
IP protection classIP41
Insulation classAC1.5KV / 1min 1mA
Maximum battery charging current from the built-in power supply, A2
Control cable length4.4 m
Net dimensions (LxWxH)320х190х400 mm
Gross dimensions (LxWxH)420х220х520 mm
Net weight8.4 kg
Gross weight8.8 kg
EAN code4260405362455

The ATS (Automatic transfer switch) unit automatically starts the generator and transfers load to it when the main power supply is disconnected.

Gasoline and diesel generators with an electric starter are equipped with a universal 6-pin connector for an automatic transfer switch unit (ATS input). The ATS unit has a PLC that allows the automatic start/stop of the generator to be programmed in the event of a power outage and after its restoration.

PROGRAMMABLE LOGIC CONTROLLER OF THE ATS UNIT:
– Automatic/manual operation
– Programming of engine starting time after power outage
– Programming of engine warm-up time before connecting to consumer
– Setting of starter operation time
– Engine performance monitoring
– Battery charging when the generator is off

The KS ATS 4/63HD ATS unit is compatible with all Könner & Söhnen diesel generators with the abbreviation “ATSR” in the article number.

The generator is suitable for connecting the ATS (Automatic Transfer Switch) system. The ATS (Automatic Transfer Switch) unit automatically starts the generator and transfers load to it when the main power supply is disconnected and automatically stops the generator when the central power supply is restored.

VTS SYSTEM

Universal generators 2 in 1 have a unique VTS (voltage Transfer Switch) phase switching system, which allows using a single generator both in single-phase mode (230V) and in three-phase mode (400V) with almost no loss of power. Each mode has its own circuit breaker. There is no need to use two separate generators.
Voltage
230/400
Max power (400V), kVA
11.25
Nominal power (400V), kVA
10.63
Max/Nominal power (230V), kW
8.1/7.7
Max/Nominal power (400V), kVA
11.25/10.63
Frequency, Hz
50
Current (max.) 230/400 V, A
36.96/16.26
Outlets
1 x Schuko 230 V, 1 x CEE 230 V 32 A, 1 x CEE 400 V 16 A, 1 x CEE 400 V 32 A, Contact strip
Avg. working time (power 50%), h***
11.4
Control panel
Multifunctional digital controller SmartGen
Noise level Lpa (7m)/Lwa, dB
67/92
Power output DC, V/А
Engine type
Diesel powered V-twin water-cooled two-cylinder, four-stroke
Engine model
KS 820HD
Engine power, hp/kW
18/13.24
Preheater
+
Fuel tank volume, l
25
Crank case volume, l
3.3
Coolant volume, l
3.5
Engine cylinder volume, cm3
794
Power output controller
Intelligent voltage stabilization system AVR
Engine start
Electric
Accumulator, A·h
45
Output for ATS
+
Net dimensions (LxWxH), mm
1250x650x760
Gross dimensions (LxWxH), mm
1300x700x880
Net weight, kg
310
Gross weight, kg
345
Protection class
IP23M
EAN code
4260405363186

Assembled in PRC.

***Fuel consumption depends on many factors, such as load, fuel quality, season, altitude, technical condition of the generator.

Related products