LPG/Gasoline Generator KS 7000E G

Available Soon
Voltage120 V
Starting watts5500 W
Running watts5000 W
Engine startrecoil/electric
Outlets4 x 20A, 1 x 50A (120V/240V)
Special functionsLPG/gasoline

DUAL FUEL series LPG/gasoline generators from Könner & Söhnen are currently the most popular among customers due to their efficiency and environmental friendliness. The generator can run on both gasoline and liquefied gas (propane-butane).

The operation of the generator on gas increases the service life of the engine. All necessary cylinder connections are included: the generator is equipped with a liquefied gas hose and two pressure reducers; just connect the generator to your cylinder. The generator is not suitable for connecting to the gas line. If necessary, LPG/gasoline models can easily be switched to gasoline mode. The powerful K&S single-cylinder air-cooled four-stroke engine ensures stable and reliable operation of the generator.

A unique feature of this range Könner & Söhnen® Generators is the ability to start and operate directly on (LPG) - there is no need to add gasoline to start.

KIT

The package includes everything you need to use LPG as fuel:

  1. Zero pressure regulator that provides gas supply during engine operation, prevents gas leakage, as well as terminates gas supply when the generator is off.
  2. 1.5 m long hose for connecting a gas cylinder provides a convenient connection.
  3. The hose is equipped with an additional reducer that is mounted on the cylinder to increase the reliability of the gas line (standard DIN 477). It provides pressure reduction and eliminates the possibility of overloading the gas connection. Just connect the generator to the cylinder and start the engine.

ENVIRONMENTALLY-FRIENDLY ENGINE

High-performance K&S engines comply with the latest EURO V emission standards. Each engine has its own individual serial number, which allows us to control the quality of production and service. The use of gas as fuel provides less emissions of harmful exhaust substances into the atmosphere.

ECONOMICAL CHOICE

The use of gas as fuel significantly reduces fuel costs for operation of the device, and the difference in value between the gasoline powered generator and the DUAL FUEL hybrid generator from TM K&S quickly pays off.

Versatility of use

You can use generator with both a portable gas cylinder and with a stationary capacity for gas storage (gasholder). Connection has to be made by a certified specialist. The pressure in the supply system must not exceed 16 Bar.

IMPROVED ENGINE EFFICIENCY

When operated on liquefied gas, the engine provides less vibration in a way that facilitates long and stable generator operation and increases engine service life.

ALTERNATOR WITH 100% COPPER WINDING

TM Könner & Söhnen generators are equipped with a high-end synchronous alternator with 100% copper winding. It is only the copper winding that can withstand maximum loads without any damage to ensure long-term reliable operation of the generator set.

CONVENIENT ERGONOMIC CONTROL PANEL with electric start

Generator’s ergonomic control panel allows you to easily control its operation due to the convenient functions location: a modern LED display (counter hours, frequency, voltage), electric start, emergency (circuit breaker) switch, low oil level sensor, outlets, terminals and more.

STEEL TANK

“Könner & Söhnen” generators are equipped with an enlarged steel fuel tank, which extends the generator’s operating time without refueling. The fuel level indicator is located on the tank for ease of use.

DAMPERS TO LOWER VIBRATION

All models of the Könner & Söhnen generators are equipped with rubber feet to reduce vibrations. Thanks to the rubber damper, the working generator will not damage the floor covering, and the frame coating will not be scratched.
Voltage, V
120
Starting watts, W
5500
Running watts, W
5000
Frequency, Hz
60**
Outlets
4 x 20A, 1 x 50A (120V/240V)
Fuel tank volume
6.60 gal. (25L)
Run time @50% (gasoline), h***
17
LED display
Voltage, frequency, working hours
Noise level Lpa (23 ft.)/Lwa, dB
70/95
Power output DC, V/А
12/8.3
Engine model
KS 390
Engine type
LPG/gasoline powered one-cylinder, four-stroke air-cooled
Engine power, hp/kW
13.0/9.56
Crank case volume
37 fl. oz (1.1L)
Engine cylinder volume, cc
389
Power output controller
Intelligent voltage stabilization system AVR
Engine start
recoil/electric
Alternator winding
Copper
Net dimensions (LxWxH)
26.7”x21.4”x21.6”
Gross dimensions (LxWxH)
27.5”x21.4”x23.2”
Net weight, lbs
170
Gross weight, lbs
175.4
Protection class
IP23M

**In transient modes, the frequency of the generator can change in the short term, that is, during normal operation of the generator, the deviation of the frequency indicator is permissible. Depending on the type of generator, engine and operating mode, the frequency can be 49-54Hz

*** Fuel consumption depends on many factors, such as load, fuel quality, season, altitude, technical condition of the generator.