Gasoline generators

Gasoline Generator "Könner & Söhnen" KS 2900

Voltage230 V
Max power2.9 kW
Nominal power2.5 kW
Engine startManual
Outlets2 x Schuko 230 V
Special functionsGasoline

LPG/Gasoline Generator "Könner & Söhnen" KS 2900G

Voltage230 V
Max power2.9 kW
Nominal power2.5 kW
Engine startManual
Outlets2 x Schuko 230 V
Special functionsLPG/gasoline

Gasoline generator "Könner & Söhnen" KS 3000

Voltage230 V
Max power3.0 kW
Nominal power2.6 kW
Engine startManual
Outlets2 x Schuko 230 V
Special functionsGasoline

Gasoline generator "Könner & Söhnen" KS 3000E

Voltage230 V
Max power3.0 kW
Nominal power2.6 kW
Engine startManual/electric
Outlets2 x Schuko 230 V
Special functionsGasoline

LPG/Gasoline Generator "Könner & Söhnen" KS 3000G

Voltage230 V
Max power3.0 kW
Nominal power2.6 kW
Engine startManual
Outlets2 x Schuko 230 V
Special functionsLPG/gasoline

LPG/Gasoline Generator "Könner & Söhnen" KS 5000E G

Voltage230 V
Max power4.5 kW
Nominal power4.0 kW
Engine startManual/electric
Outlets2 x Schuko 230 V
Special functionsLPG/gasoline

Gasoline generator "Könner & Söhnen" KS 7000

Voltage230 V
Max power5.5 kW
Nominal power5.0 kW
Engine startManual
Outlets1 x Schuko 230 V, 1 x CEE 230 V 32 A
Special functionsGasoline

Gasoline generator "Könner & Söhnen" KS 7000E

Voltage230 V
Max power5.5 kW
Nominal power5.0 kW
Engine startManual/electric
Outlets1 x Schuko 230 V, 1 x CEE 230 V 32 A
Special functionsGasoline

LPG/Gasoline Generator "Könner & Söhnen" KS 7000E G

Voltage230 V
Max power5.5 kW
Nominal power5.0 kW
Engine startManual/electric
Outlets1 x Schuko 230 V, 1 x CEE 230 V 32 A
Special functionsLPG/gasoline

Gasoline generator "Könner & Söhnen" KS 7000E-3

Voltage400 V
Max power5.5 kW
Nominal power5.0 kW
Engine startManual/electric
Outlets1 x Schuko 230 V, 1 x CEE 400 V 16 A
Special functionsGasoline

Gasoline generator "Könner & Söhnen" KS 7000E 1/3

Voltage230/400 V
Max power (230V)5.5 kW
Nominal power (230V)5.0 kW
Max power (400V)5.5 kW
Nominal power (400V)5.0 kW
Engine startManual/electric
Outlets1 x CEE 230 V 32 A, 1 x CEE 400 V 16 A
Special functionsVTS 230/400 V, Gasoline

Gasoline generator "Könner & Söhnen" KS 7000E ATS

Voltage230 V
Max power5.5 kW
Nominal power5.0 kW
Engine startManual/electric/auto
Outlets1 x Schuko 230 V, 1 x CEE 230 V 32 A
Special functionsBuilt-in ATS, Gasoline

Gasoline generator "Könner & Söhnen" KS 7000E-3 ATS

Voltage400 V
Max power (400V)5.5 kW
Nominal power (400V)5.0 kW
Max power5.5 kW
Nominal power5.0 kW
Engine startManual/electric/auto
Outlets1 x Schuko 230 V, 1 x CEE 400 V 16 A
Special functionsBuilt-in ATS, Gasoline

LPG/Gasoline Generator "Könner & Söhnen" KS 9000E G

Voltage230 V
Max power6.5 kW
Nominal power6.0 kW
Engine startManual/electric
Outlets1 x Schuko 230 V, 1 x CEE 230 V 32 A
Special functionsLPG/gasoline

Gasoline generator "Könner & Söhnen" KS 10000E

Voltage230 V
Max power8.0 kW
Nominal power7.5 kW
Engine startManual/electric
Outlets1 x Schuko 230 V, 1 x CEE 230 V 32 A
Special functionsGasoline

LPG / Gasoline generator "Könner & Söhnen" KS 10000E G

Voltage230 V
Max power8.0 kW
Nominal power7.5 kW
Engine startManual/electric
Outlets1 x Schuko 230 V, 1 x CEE 230 V 32 A
Special functionsLPG/gasoline

Gasoline generator "Könner & Söhnen" KS 10000E ATS

Voltage230 V
Max power8.0 kW
Nominal power7.5 kW
Engine startManual/electric/auto
Outlets1 x Schuko 230 V, 1 x CEE 230 V 32 A
Special functionsBuilt-in ATS, Gasoline

Gasoline generator "Könner & Söhnen" KS 10000E 1/3

Voltage230/400 V
Max power (230V)8.0 kW
Nominal power (230V)7.5 kW
Max power (400V)8.0 kW
Nominal power (400V)7.5 kW
Engine startManual/electric
Outlets1 x CEE 230 V 32 A, 1 x CEE 400 V 16 A
Special functionsVTS 230/400 V, Gasoline

Gasoline generator "Könner & Söhnen" KS 10000E-3

Voltage400 V
Max power8.0 kW
Nominal power7.5 kW
Engine startManual/electric
Outlets1 x Schuko 230 V, 1 x CEE 400 V 16 A
Special functionsGasoline

Gasoline generator "Könner & Söhnen" KS 10000E-3 ATS

Voltage400 V
Max power8.0 kW
Nominal power7.5 kW
Engine startManual/electric/auto
Outlets1 x Schuko 230 V, 1 x CEE 400 V 16 A
Special functionsBuilt-in ATS, Gasoline

Gasoline generator "Könner & Söhnen" KS 12-1E ATSR

Voltage230 V
Max power9.2 kW
Nominal power9.0 kW
Engine startManual/electric
Outlets1 x Schuko 230 V, 1 x CEE 230 V 32 A, 1 x CEE 230 V 63 A
Special functionsGasoline, ATS output

Gasoline generator "Könner & Söhnen" KS 12-1E 1/3 ATSR

Voltage230/400 V
Max power (230V)8.2 kW
Nominal power (230V)8.0 kW
Max power (400V)11.5 kVA
Nominal power (400V)11.25 kVA
Engine startManual/electric
Outlets1 x Schuko 230 V, 1 x CEE 230 V 32 A, 1 x CEE 400 V 32 A
Special functionsVTS 230/400 V, Gasoline, ATS output

2-cylinders gasoline generator "Könner & Söhnen" KS 15-1E ATSR

Voltage230 V
Max power12.5 kW
Nominal power12.0 kW
Engine startElectric
Outlets1 x Schuko 230 V, 1 x CEE 230 V 32 A, 1 x CEE 230 V 63 A
Special functionsGasoline, ATS output

Gasoline generator "Könner & Söhnen" KS 15-1E 1/3 ATSR

Voltage230/400 V
Max power (230V)11.5 kW
Nominal power (230V)11.0 kW
Max power (400V)15.6 kVA
Nominal power (400V)15.0 kVA
Engine startElectric
Outlets1 x CEE 230 V 32 A, 1 x CEE 230 V 63 A
Special functionsVTS 230/400 V, Gasoline, ATS output

Transportation kit KS 3 KIT

Includes:
Wheels – 2 pcs.
Handles – 2 pcs.
Support legs – 2 pcs.
Mounting kit – 1 pc.

Suitable for all modifications of gasoline generators KS 2900, KS 3000.

Diameter20.5 cm
Diameter of the frame26 mm

Transportation kit KS 7 KIT

Includes:
Wheels – 2 pcs.
Handles – 2 pcs.
Support legs – 2 pcs.
Mounting kit – 1 pc.

Suitable for all modifications of gasoline generators: KS 5000, KS 7000 (28mm diameter frame).

Diameter20.5 cm
Diameter of the frame28 mm

Transportation kit KS 10 KIT

Includes:
Wheels – 2 pcs.
Handles – 2 pcs.
Support legs – 2 pcs.
Mounting kit – 1 pc.

Suitable for all modifications of KS 9000, KS 10000 gasoline generators with 32mm diameter frame.

Diameter20.5 cm
Diameter of the frame32 mm

Content: Main Point: where to Install a gasoline generator

Main Point: where to Install a gasoline generator?

With constant power outages, a gasoline generator will be a valuable purchase. Many modern private house owners in Ukraine already have such a device or are trying to purchase one. In this regard, the logical question would be – where to install a gasoline generator? Please read the owner's manual before purchasing and consider all the recommendations. The manual can be found on our website in the "Support" tab. What is the ideal area to install a gasoline generator? A few basic recommendations:

  1. It is desirable to install the device outside the living area, and, if possible, outside the house. This will keep odors out of the living quarters and reduce the noise level.
  2. The installation area must be covered. This will protect the gasoline generator from rain, snow, frost, sunlight, and wind.
  3. The installation area must be safe (in terms of fire protection). The device must not be installed near flammable objects. A diesel Popular products are found in gasoline generators

Buy gasoline generators, for example, is a frequent request. First of all, because conveniences such as water, electricity, gas are not available everywhere. No electricity – no heat, but people don't want to stay in the cold. Secondly, such a purchase will be very popular in distant corners of the country. The farther the residential area, the more expensive it is to lay the service lines. And if there are any, then, undoubtedly, there will be electricity failures, heating failures (if operated by electricity), and so on. The gasoline generator solves such problems. But be careful when choosing a model. If you want to use the generator as a backup power source, then you need to correctly calculate the total power consumption, taking into account the operation of several devices at the same time. A good unit should provide the necessary power reserve. We can offer more. About generators ► inverter generators . More on our social networks facebook


Choosing the engine start type when buying a generator

In the event of a power outage, the generator is used as a house backup power source. When choosing a device for a country house, you will be faced with parameter options. For example, there are units with different engine start types: manual, electric, and automatic transfer switch (ATS). Tip 1. The gasoline generator can also be filled with motor oil. When choosing the oil type, it is advisable to take into account the ambient temperature of the region, where the generator is operated. Choose only high-quality synthetic oil, since the service life of the purchased device directly depends on it. We recommend using Könner & Söhnen 10W-30 motor oil. Tip 2. Most often, the generator tank is filled with gasoline not at the gas station. Special cans are used to transport gasoline. It's important to keep the can clean, since the presence of debris, dust, or water in it is unacceptable. If even a small amount of water gets into the tank, the device will be damaged. We recommend using KS CAN 10 or KS CAN 5 fuel cans (10L and 5L capacity respectively). Tip 3. When starting the engine for the first time, the test run is one of the critical moments. It starts with the engine running for two hours at 50% load. The oil level must be monitored and replaced after 20 hours of operation. Tip 4. When choosing a specific model, special attention should be paid to generators with built-in ATS. Imagine you are not at home. Suddenly the power supply from the main network stops, as well as heating (if operated by electricity), and hot water (the same reason). The house gets completely frozen, the refrigerator does not work. And if you've gone on a journey, the premises may become damp at all. Your relatives may not be able to turn on the generator manually on their own, since they do not understand the technical aspects of starting the unit. Consider this fact when buying the generator. Make a choice based on your own benefit and needs. In general, the manual start procedure looks as follows:

  1. Read the owner's manual.
  2. Check the level of oil and fuel in the tank.
  3. Open the fuel valve.
  4. Close the air choke
  5. Grasp the starter handle and slowly pull it until resistance is felt. Pull the starter cord to the full length with a sharp movement.
  6. Set the engine start key to the ON position and hold it for a few seconds until the engine starts.
  7. Open the air choke. Allow the generator to run for a short time without any load before the engine starts to run smoothly.

Connect the generator to the power consumers. As you can see, it's no big deal. All the moves will be carried out more quickly when you repeat the procedure several times. Please find the description here. About generators ► diesel generators


Gasoline generator – expert manual start lifehacks?

First of all, let's define: what is an inverter gasoline generator? This device is an alternative solution to the classic one. Main advantages:

  • lower noise level;
  • small dimensions (commonly);
  • supports connection of supersensitive devices;
  • fuel-saving;
  • mobile assemblies are good for a nature trip.

For sure, the inverter gasoline generator has its advantages. Regarding disadvantages, a limited power range is probably a significant one. The maximum power is often no more than 8 kW. The compact inverter generator, however, will be indispensable outdoors, since it's handy enough to take it on a fishing trip or on vacation. It is small in size, so it can easily fit into the trunk of a car. It can be used to connect the necessary devices, which is very practical. Besides, it's quite possible to find the model for any budget. Most importantly, don't forget to consult with a specialist regarding the generator installation and operation. We can offer other products Inverter generators K&S